HF-Regulator II for TL-D lamps Fluorescent Electronic Gear

From € 45,33 incl. VAT
From € 45,33 ex. VAT
See variants (5)

Select your product from the 5

 HF-R 136 TL-D EII 220-240V 50/60Hz
Product code: 58380 Line Frequency: 50/60 Hz Full product code: 913700609266 Full product name: HF-R 136 TL-D EII 220-240V 50/60Hz Order code: 913700609266 Order product name: HF-R 136 TL-D EII 220-240V 50/60Hz Packing configuration: 12 Pieces per pack: 1 Bar code on outerbox - EAN3: 8711500910141 Bar code on pack - EAN1: 8711500910134 Packs per outerbox: 12 see more »
Logistic code(s) - 12NC: 913700609266 Net weight per piece: 0.260 kg Length A1: 360 mm CE marking: Yes Height C1: 22 mm T-ambient: 10 (min), 50 (max) C Width B1: 30 mm Lifetime 90% surv.@Tcaselife: 50000 hr Fixing Hole Diameter D1: 4.2 mm Fixing Hole Distance Length A2: 350 mm Inrush current Peak: 27 (max) A Earth leakage current: 0.5 (max) mA Inrush current Width: 0.25 ms T-storage: -25 (min), 80 (max) C Rated Lamptype: TL-D Line Voltage: 220-240 V Rated Ballast-Lamp Power: 36 Rated Number of Lamps: 1 piece Approval marks: ENEC / VDE-EMV Automatic restart: Yes Energy Efficiency Index: A1 Housing: L 360x30x21 Mains voltage safety (AC): -10%/+10% Mains voltage performance (AC): -8%/+6% Power losses gear: 5.5 W PowerFactor 100% output power: 0.95 - Overvoltage protection 320Vac: 48 hr Overvoltage protection 350Vac: 2 hr Crestfactor: 1.7 (max) - Max ballast on MCB(16A type B): 28 x Hum and Noise level: Inaudible Conn.type input terminals: WAGO 251 universal connector [Suitable for both automatic wiring (ALF and ADS) and manual wiring] Conn.type output terminals: WAGO 251 universal connector [Suitable for both automatic wiring (ALF and ADS) and manual wiring] Striplength: 8.0-9.0 mm Dual fixture Master/Slave: Not applicable [Master/Slave oper. not applicable] Wcs Input terminals: 0.50-1.00 mm2 Wcs Output terminals: 0.50-1.00 mm2 Bumps: IEC 68-2-29 Eb EMI 9kHz .. 30 MHz: EN 55015 Vibrations: IEC 68-2-6 Fc Application code: EII Interface: 1-10V Ignition Method: Programmed Start Ignition time: 0.2 (max) s Operating frequency: 45 (min), 89 (max) kHz Regulating level power: 1%-100% Battery voltage lamp ignition: 196 V Battery voltage running lamps: 154-276 Control input protection: Yes (Basic insulation) Conn.type ctrl input terminals: WAGO 251 universal connector [Suitable for both automatic wiring (ALF and ADS) and manual wiring] Total Harmonic Distortion EUR: 7 % Wcs Control input terminals: 0.50-1.00 mm2 T-ignition: 0 (min), 50 (max) C Wcs auto insertion (ALF/ADS): 0.5 mm2 EMI 30 MHz .. 1000MHz: EN 55022 level B [Level = Class] Performance Standard: IEC 60929 Safety Standard: IEC 61347-2-3 Environmental Standard: ISO 14001 Quality Standard: ISO 9000:2000 Harmonic current emissions: IEC 61000-3-2 EMC Immunity: IEC 61547 Humidity: EN 61347-2-3 clause 11 Emergency standard: IEC 60598-2-22 Temperature marking: 110 [Yes] « hide more
€ 45,33 € 45,33 ex. VAT
pc(s)
pc(s)
 HF-R 158 TL-D EII 220-240V 50/60Hz
Product code: 58381 Line Frequency: 50/60 Hz Full product code: 913700609466 Full product name: HF-R 158 TL-D EII 220-240V 50/60Hz Order code: 913700609466 Order product name: HF-R 158 TL-D EII 220-240V 50/60Hz Packing configuration: 12 Pieces per pack: 1 Bar code on outerbox - EAN3: 8711500910189 Bar code on pack - EAN1: 8711500910172 Packs per outerbox: 12 see more »
Logistic code(s) - 12NC: 913700609466 Net weight per piece: 0.270 kg Length A1: 360 mm CE marking: Yes Height C1: 22 mm T-ambient: -20 (min), 50 (max) C Width B1: 30 mm Lifetime 90% surv.@Tcaselife: 50000 hr Fixing Hole Diameter D1: 4.2 mm Fixing Hole Distance Length A2: 350 mm Inrush current Peak: 27 (max) A Earth leakage current: 0.5 (max) mA Inrush current Width: 0.25 ms T-storage: -25 (min), 80 (max) C Rated Lamptype: TL-D Line Voltage: 220-240 V Rated Ballast-Lamp Power: 58 Rated Number of Lamps: 1 piece Approval marks: ENEC / VDE-EMV Automatic restart: Yes Energy Efficiency Index: A1 Housing: L 360x30x21 Mains voltage safety (AC): -10%/+10% Mains voltage performance (AC): -8%/+6% Power losses gear: 6.3 W PowerFactor 100% output power: 0.97 - Overvoltage protection 320Vac: 48 hr Overvoltage protection 350Vac: 2 hr Crestfactor: 1.7 (max) - Max ballast on MCB(16A type B): 28 x Hum and Noise level: Inaudible Conn.type input terminals: WAGO 251 universal connector [Suitable for both automatic wiring (ALF and ADS) and manual wiring] Conn.type output terminals: WAGO 251 universal connector [Suitable for both automatic wiring (ALF and ADS) and manual wiring] Striplength: 8.0-9.0 mm Dual fixture Master/Slave: Not applicable [Master/Slave oper. not applicable] Wcs Input terminals: 0.50-1.00 mm2 Wcs Output terminals: 0.50-1.00 mm2 Bumps: IEC 68-2-29 Eb EMI 9kHz .. 30 MHz: EN 55015 Vibrations: IEC 68-2-6 Fc Application code: EII Interface: 1-10V Ignition Method: Programmed Start Ignition time: 0.2 (max) s Operating frequency: 45 (min), 105 (max) kHz Regulating level power: 1%-100% Battery voltage lamp ignition: 196 V Battery voltage running lamps: 154-276 Control input protection: Yes (Basic insulation) Conn.type ctrl input terminals: WAGO 251 universal connector [Suitable for both automatic wiring (ALF and ADS) and manual wiring] Total Harmonic Distortion EUR: 6 % Wcs Control input terminals: 0.50-1.00 mm2 T-ignition: 0 (min), 50 (max) C Wcs auto insertion (ALF/ADS): 0.5 mm2 EMI 30 MHz .. 1000MHz: EN 55022 level B [Level = Class] Performance Standard: IEC 60929 Safety Standard: IEC 61347-2-3 Environmental Standard: ISO 14001 Quality Standard: ISO 9000:2000 Harmonic current emissions: IEC 61000-3-2 EMC Immunity: IEC 61547 Humidity: EN 61347-2-3 clause 11 Emergency standard: IEC 60598-2-22 Temperature marking: 110 [Yes] « hide more
€ 45,33 € 45,33 ex. VAT
pc(s)
pc(s)
 HF-R 236 TL-D EII 220-240V 50/60Hz
Product code: 58383 Line Frequency: 50/60 Hz Full product code: 913700609366 Full product name: HF-R 236 TL-D EII 220-240V 50/60Hz Order code: 913700609366 Order product name: HF-R 236 TL-D EII 220-240V 50/60Hz Packing configuration: 12 Pieces per pack: 1 Bar code on outerbox - EAN3: 8711500910165 Bar code on pack - EAN1: 8711500910158 Packs per outerbox: 12 see more »
Logistic code(s) - 12NC: 913700609366 Net weight per piece: 0.295 kg Length A1: 360 mm CE marking: Yes Height C1: 22 mm T-ambient: 10 (min), 50 (max) C Width B1: 30 mm Lifetime 90% surv.@Tcaselife: 50000 hr Fixing Hole Diameter D1: 4.2 mm Fixing Hole Distance Length A2: 350 mm Inrush current Peak: 45 (max) A Earth leakage current: 0.5 (max) mA Inrush current Width: 0.40 ms T-storage: -25 (min), 80 (max) C Rated Lamptype: TL-D Line Voltage: 220-240 V Rated Ballast-Lamp Power: 36 Rated Number of Lamps: 2 piece Approval marks: ENEC / VDE-EMV Automatic restart: Yes Energy Efficiency Index: A1 Housing: L 360x30x21 Mains voltage safety (AC): -10%/+10% Mains voltage performance (AC): -8%/+6% Power losses gear: 7.3 W PowerFactor 100% output power: 0.98 - Overvoltage protection 320Vac: 48 hr Overvoltage protection 350Vac: 2 hr Crestfactor: 1.7 (max) - Max ballast on MCB(16A type B): 12 x Hum and Noise level: Inaudible Conn.type input terminals: WAGO 251 universal connector [Suitable for both automatic wiring (ALF and ADS) and manual wiring] Conn.type output terminals: WAGO 251 universal connector [Suitable for both automatic wiring (ALF and ADS) and manual wiring] Striplength: 8.0-9.0 mm Wcs Input terminals: 0.50-1.00 mm2 Wcs Output terminals: 0.50-1.00 mm2 Bumps: IEC 68-2-29 Eb EMI 9kHz .. 30 MHz: EN 55015 Vibrations: IEC 68-2-6 Fc Application code: EII Interface: 1-10V Ignition Method: Programmed Start Ignition time: 0.2 (max) s Operating frequency: 45 (min), 89 (max) kHz Regulating level power: 1%-100% Battery voltage lamp ignition: 196 V Battery voltage running lamps: 154-276 Control input protection: Yes (Basic insulation) Conn.type ctrl input terminals: WAGO 251 universal connector [Suitable for both automatic wiring (ALF and ADS) and manual wiring] Total Harmonic Distortion EUR: 5 % Wcs Control input terminals: 0.50-1.00 mm2 T-ignition: 0 (min), 50 (max) C Wcs auto insertion (ALF/ADS): 0.5 mm2 EMI 30 MHz .. 1000MHz: EN 55022 level B [Level = Class] Performance Standard: IEC 60929 Safety Standard: IEC 61347-2-3 Environmental Standard: ISO 14001 Quality Standard: ISO 9000:2000 Harmonic current emissions: IEC 61000-3-2 EMC Immunity: IEC 61547 Humidity: EN 61347-2-3 clause 11 Emergency standard: IEC 60598-2-22 Temperature marking: 110 [Yes] « hide more
€ 52,94 € 52,94 ex. VAT
pc(s)
pc(s)
 HF-R 258 TL-D EII 220-240V 50/60Hz
Product code: 58384 Line Frequency: 50/60 Hz Full product code: 913700609566 Full product name: HF-R 258 TL-D EII 220-240V 50/60Hz Order code: 913700609566 Order product name: HF-R 258 TL-D EII 220-240V 50/60Hz Packing configuration: 12 Pieces per pack: 1 Bar code on outerbox - EAN3: 8711500910202 Bar code on pack - EAN1: 8711500910196 Packs per outerbox: 12 see more »
Logistic code(s) - 12NC: 913700609566 Net weight per piece: 0.325 kg Length A1: 360 mm CE marking: Yes Height C1: 22 mm T-ambient: 10 (min), 50 (max) C Width B1: 30 mm Lifetime 90% surv.@Tcaselife: 50000 hr Fixing Hole Diameter D1: 4.2 mm Fixing Hole Distance Length A2: 350 mm Inrush current Peak: 45 (max) A Earth leakage current: 0.5 (max) mA Inrush current Width: 0.40 ms T-storage: -25 (min), 80 (max) C Rated Lamptype: TL-D Line Voltage: 220-240 V Rated Ballast-Lamp Power: 58 Rated Number of Lamps: 2 piece Approval marks: ENEC / VDE-EMV Automatic restart: Yes Energy Efficiency Index: A1 Housing: L 360x30x21 Mains voltage safety (AC): -10%/+10% Mains voltage performance (AC): -8%/+6% Power losses gear: 11.2 W PowerFactor 100% output power: 0.98 - Overvoltage protection 320Vac: 48 hr Overvoltage protection 350Vac: 2 hr Crestfactor: 1.7 (max) - Max ballast on MCB(16A type B): 12 x Hum and Noise level: Inaudible Conn.type input terminals: WAGO 251 universal connector [Suitable for both automatic wiring (ALF and ADS) and manual wiring] Conn.type output terminals: WAGO 251 universal connector [Suitable for both automatic wiring (ALF and ADS) and manual wiring] Striplength: 8.0-9.0 mm Wcs Input terminals: 0.50-1.00 mm2 Wcs Output terminals: 0.50-1.00 mm2 Bumps: IEC 68-2-29 Eb EMI 9kHz .. 30 MHz: EN 55015 Vibrations: IEC 68-2-6 Fc Application code: EII Interface: 1-10V Ignition Method: Programmed Start Ignition time: 0.2 (max) s Operating frequency: 45 (min), 105 (max) kHz Regulating level power: 1%-100% Battery voltage lamp ignition: 196 V Battery voltage running lamps: 154-276 Control input protection: Yes (Basic insulation) Conn.type ctrl input terminals: WAGO 251 universal connector [Suitable for both automatic wiring (ALF and ADS) and manual wiring] Total Harmonic Distortion EUR: 4 % Wcs Control input terminals: 0.50-1.00 mm2 T-ignition: 0 (min), 50 (max) C Wcs auto insertion (ALF/ADS): 0.5 mm2 EMI 30 MHz .. 1000MHz: EN 55022 level B [Level = Class] Performance Standard: IEC 60929 Safety Standard: IEC 61347-2-3 Environmental Standard: ISO 14001 Quality Standard: ISO 9000:2000 Harmonic current emissions: IEC 61000-3-2 EMC Immunity: IEC 61547 Humidity: EN 61347-2-3 clause 11 Emergency standard: IEC 60598-2-22 Temperature marking: 110 [Yes] « hide more
€ 52,94 € 52,94 ex. VAT
pc(s)
pc(s)
 HF-R 418 TL-D EII 220-240V 50/60Hz
Product code: 58386 Line Frequency: 50-60 Hz Full product code: 913700614666 Full product name: HF-R 418 TL-D EII 220-240V 50/60Hz Order code: 913700614666 Order product name: HF-R 418 TL-D EII 220-240V 50/60Hz Packing configuration: 10 Pieces per pack: 1 Bar code on outerbox - EAN3: 8711500913678 Bar code on pack - EAN1: 8711500913661 Packs per outerbox: 10 see more »
Logistic code(s) - 12NC: 913700614666 Net weight per piece: 0.370 kg Length A1: 359 mm CE marking: Yes Height C1: 22 mm T-ambient: -20 (min), 50 (max) C Width B1: 39 mm Lifetime 90% surv.@Tcaselife: 50000 hr Fixing Hole Diameter D1: 4.2 mm Fixing Hole Distance Length A2: 350 mm Inrush current Peak: 45 (max) A Earth leakage current: 0.5 (max) mA Inrush current Width: 0.40 ms T-storage: -25 (min), 80 (max) C Rated Lamptype: TL-D Line Voltage: 220-240 V Rated Ballast-Lamp Power: 18 Rated Number of Lamps: 4 piece Approval marks: ENEC / VDE-EMV Automatic restart: Yes Energy Efficiency Index: A1 Housing: L 359x39x22 Mains voltage safety (AC): -10%/+10% Mains voltage performance (AC): -8%/+6% Power losses gear: 13.4 W PowerFactor 100% output power: 0.98 - Overvoltage protection 320Vac: 48 hr Overvoltage protection 350Vac: 2 hr Crestfactor: 1.7 (max) - Max ballast on MCB(16A type B): 12 x Hum and Noise level: Inaudible Conn.type input terminals: WAGO 251 universal connector [Suitable for both automatic wiring (ALF and ADS) and manual wiring] Conn.type output terminals: WAGO 251 universal connector [Suitable for both automatic wiring (ALF and ADS) and manual wiring] Striplength: 8.0-9.0 mm Wcs Input terminals: 0.50-1.00 mm2 Wcs Output terminals: 0.50-1.00 mm2 Bumps: IEC 68-2-29 Eb EMI 9kHz .. 30 MHz: EN 55015 Vibrations: IEC 68-2-6 Fc Application code: EII Interface: 1-10V Ignition Method: Programmed Start Ignition time: 0.2 (max) s Operating frequency: 46 (min), 97 (max) kHz Regulating level power: 1%-100% Battery voltage lamp ignition: 196 V Battery voltage running lamps: 154-276 Control input protection: Yes (Basic insulation) Conn.type ctrl input terminals: WAGO 251 universal connector [Suitable for both automatic wiring (ALF and ADS) and manual wiring] Total Harmonic Distortion EUR: 4 % Wcs Control input terminals: 0.50-1.00 mm2 T-ignition: 0 (min), 50 (max) C Wcs auto insertion (ALF/ADS): 0.5 mm2 EMI 30 MHz .. 1000MHz: EN 55022 level B [Level = Class] Performance Standard: IEC 60929 Safety Standard: IEC 61347-2-3 Environmental Standard: ISO 14001 Quality Standard: ISO 9000:2000 Harmonic current emissions: IEC 61000-3-2 EMC Immunity: IEC 61547 Humidity: EN 61347-2-3 clause 11 Emergency standard: IEC 60598-2-22 Temperature marking: 110 [Yes] « hide more
€ 66,77 € 66,77 ex. VAT
pc(s)
pc(s)

High-frequency electronic dimming ballast, using the analog protocol (1-10 V) for TL-D lamps

Features

Programmed start: flicker-free ignition < 0.5 seconds and striation-free operation, no stroboscopic effects. Preheating the lamp electrodes enables the lamps to be switched on and off without reducing life
Smart power ensures constant light, independent of mains fluctuations.
Up to 60% reduction in energy consumption by using automatic lighting control systems
Stop circuit is activated within 5 seconds in the event of lamp failure (safety stop), and ballast resets automatically after lamp replacement

Applications

Indoor, general and task lighting applications in combination with lighting control systems (personal control, daylight linking and/or movement detection)

If you buy goods in partial package that is not currently available in our store (available on request), we reserve the rights to charge additional increments of 5 EUR ex. VAT.

Recommended also

 Philips HF-Essential for TL5/TL-D
Rated 5.0/5 based on 1 customer reviews
from 7,81
 Osram QUICKTRONIC QTz8
Rated 5.0/5 based on 1 customer reviews
from 8,69
 Tridonic PC T8 TEC, 18 - 58 W
Rated 5.0/5 based on 1 customer reviews
from 7,67
 Philips HF-Matchbox Blue
Rated 5.0/5 based on 1 customer reviews
from 7,62
 Tridonic PCA T5 ECO lp xitec II, 14 - 80 W
Rated 5.0/5 based on 1 customer reviews
76,06
 Tridonic PCA T5 BASIC lp xitec II, 14 - 80 W
Rated 5.0/5 based on 1 customer reviews
from 67,17
 Tridonic PCA T5 EXCEL one4all lp xitec II, 14 - 80 W
Rated 5.0/5 based on 1 customer reviews
from 63,49
 Tridonic PC TC PRO, 1/2x9 - 70 W
Rated 5.0/5 based on 1 customer reviews
from 17,48
 Tridonic PCA TC EXCEL one4all xitec II, 18 - 57 W
Rated 5.0/5 based on 1 customer reviews
from 71,77
 Tridonic PCA TC ECO xitec II, 11 &ndash; 57 W
Rated 5.0/5 based on 1 customer reviews
from 73,61
 Tridonic PC T8 TOP lp, PC T8 TOP sl, 18 - 58 W
Rated 5.0/5 based on 1 customer reviews
from 11,35
 Tridonic PC CFL COMBO, 220 - 240 V 50/60 Hz
Rated 5.0/5 based on 1 customer reviews
from 82,81
HF-Regulator II for TL-D lamps
Rated 5.0/5 based on 1 customer reviews
Power Supplies, Ballasts, Transformers / Fluorescent Electronic Gear

Philips https://www.electrico24.eu/uploads/producer_logos/faeccaa67c65b0428b3eca6021a3815d.jpg

HF-Regulator II for TL-D lamps
199.53 PLN available
 Philips HF-Regulator II for TL-D lamps

Recommended

LED street luminaire GitLighting With Brigdelux LEDs
Rated 5.0/5 based on 1 customer reviews
from 103,64
 GitLighting Gemini 18 LED Solar Street Light 1300lm, 3 modes
Rated 5.0/5 based on 1 customer reviews
192,05
LED street luminaire GitLighting WHL COB Epistar
Rated 5.0/5 based on 1 customer reviews
from 48,16
Microwave movement sensor Kanlux ROLF MINI JQ-L
Rated 5.0/5 based on 1 customer reviews
6,45
Hermetic wall & ceiling light luminaire Kanlux MARC DL-60
Rated 5.0/5 based on 1 customer reviews
11,03
 GitLighting Gemini 22 Solar Street Light 40xLED, 24W, 2500lm, 3 modes
Rated 5.0/5 based on 1 customer reviews
332,83

Blog posts

Osram and Philips light sources types

Wondering how to select a light source for luminaire? Below is a list of popular light sources of Osram and Philips with base information and the light source indication. Fluorescent Linear and Circular   Base Power (W) Luminous flux (lm) OSRAM PHILIPS Fluorescent Linear T5 (T16) G5 8 400 Basic T5Short L 8W TL MiniStandard TL Mini 8W 14 200... read more »


Our other brands

Elektriko.pl - oprawy oświetleniowe i źródła światła Electric24.pl Hydrauliko.pl

e-Gazele Biznesu 37. place in Poland in the ranking e-Gazele Biznesu 2016.
"Golden Payer 2015" award from Euler Hermes.
Golden payer Golden payer 2016 Export

Logisoft company has 18 years - we began 14 August 2006. 25959 companies have trusted us. We offer 3 072 products.