Operating frequency |
0.165 kHz |
Power factor λ |
0.95 |
Length |
133.0 mm |
Dimmable |
No |
Input voltage AC |
220
240 V |
Mains frequency |
50
60 Hz |
ECG efficiency |
90 % |
Inrush current |
30 A |
Max. no. of ECGs on circuit breaker 10 A |
15 |
Max. no. of ECGs on circuit breaker 16 A |
26 |
Surge capability (L-N) |
3 kV |
Surge capability (L/N-Ground) |
4 kV |
Width |
77.0 mm |
Height |
48.0 mm |
Mounting hole spacing, length |
123.0 mm |
Cable cross-section, input side |
0.5
2.5 mm² |
Product weight |
730.00 g |
Cable cross-section, output side |
0.5
2.5 mm² |
Casing material |
Plastic |
Wire preparation length, input side |
10
11 mm |
Ambient temperature range |
-25
+60 °C |
Maximum temperature at tc test point |
75 °C |
ECG lifetime |
60000 h |
Suitable for fixtures with prot. class |
I / II |
Overheating protection |
Power reduction and switch off at T > 75 °C at the tc point |
Max. cable length to lamp/LED module |
1.5 m |
Approval marks approval |
ENEC 10 / VDE / VDE-EMC / GOST / C-Tick |
Standards |
Acc. to EN 61347-2-12/Acc. to EN 55015/Acc. to EN 61000-3-2/Acc. to EN 61547 |
Type of protection |
IP20 |
U-OUT (working voltage) |
250 V |
Encapsulated |
Yes |
Design / version |
ECG outdoor |
EEI Energy Label |
A2 |
Input voltage range AC |
198
264 V |
Ignition voltage |
4.5 kVp |
Wire preparation length, output side |
10
11 mm |
Lamp wattage |
39 W |
Line current |
0.20 A |
System wattage |
43.00 W |
Max. no. of ECGs on 16A MCB with EBN-OS |
65 |
Max. working voltage between LH and LL |
250 V |
Protective conductor current |
0.1 mA |
Max. capacitance of wire ECG/lamp |
120 pF |
Max. working voltage betw. LL/LH & earth |
250 V |
ECG reset time |
> 0.5 s |
Restriction on ignition time |
20 min |
Required IP rating of luminaire |
≥ 54 |
Lightning stroke protection |
With connected equipotentiality-terminal 10 surges with 10 kV acc. to IEC 61000-4-5 |
Electrical data
|
Power factor λ |
0.95 |
Input voltage AC |
220
240 V |
Mains frequency |
50
60 Hz |
Surge capability (L-N) |
3 kV |
Surge capability (L/N-Ground) |
4 kV |
U-OUT (working voltage) |
250 V |
Input voltage range AC |
198
264 V |
Ignition voltage |
4.5 kVp |
Max. working voltage between LH and LL |
250 V |
Protective conductor current |
0.1 mA |
Max. working voltage betw. LL/LH & earth |
250 V |
Dimensions & weight
|
Wire preparation length, input side |
10
11 mm |
Wire preparation length, output side |
10
11 mm |
Lifespan
|
ECG lifetime |
60000 h |
Additional product data
|
Encapsulated |
Yes |
Design / version |
ECG outdoor |
Required IP rating of luminaire |
≥ 54 |
Capabilities
|
Dimmable |
Yes |
Suitable for fixtures with prot. class |
I / II |
Max. cable length to lamp/LED module |
1.5 m |
Dimming interface |
DALI / StepDIM / AstroDIM |
ECG reset time |
> 0.5 s |
Restriction on ignition time |
20 min |
Burn-in time prior to dimming operation |
10 min |
Lightning stroke protection |
With connected equipotentiality-terminal 10 surges with 10 kV acc. to IEC 61000-4-5 |
Certificates & standards
|
Type of protection |
IP20 |
EEI Energy Label |
A2 |
Colors & materials
|
Casing material |
Plastic |